local display | Without | |
electrical connection | Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm² | |
positive opening | With | |
minimum actuation speed | 0.01 m/min | |
[Ie] rated operational current | 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A | |
[Ithe] conventional enclosed thermal current | 10 A | |
[Ui] rated insulation voltage | 300 V conforming to CSA C22.2 No 14 contact block 300 V conforming to UL 508 contact block 500 V degree of pollution 3 conforming to IEC 60947-1 contact block | |
resistance across terminals | 0.25 mOhm conforming to IEC 60255-7 category 3 | |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60664 6 kV conforming to IEC 60947-1 | |
short-circuit protection | 10 A by gG cartridge fuse | |
electrical durability | 5000000 cycles, DC-13 120 V, 4 W, operating rate: < 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13 24 V, 10 W, operating rate: < 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13 48 V, 7 W, operating rate: < 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | |
width | 1.69 in (43 mm) | |
height | 3.31 in (84 mm) | |
depth | 1.42 in (36 mm) | |
product weight | 0.66 lb(US) (0.3 kg) | |
terminals description ISO n°1 | (11-12)NC (21-22)NC (23-24)NO (13-14)NO |